1. What are the precautions involved in running with RT flex
Reliability and safety has the utmost priority
in the common rail RT-flex system.
v
The
duplicated high-pressure delivery pipes have stop cocks at both ends to isolate
any failed pipe. Each single pipe is adequate for the full delivery. All high
pressure pipes are double-walled for safety.
v
Every
injection nozzle is independently monitored and controlled by the WECS. In case
of difficulties, such as a broken high pressure line or a malfunctioning
injector, the affected injection valve can be cut out individually without
losing the entire cylinder.
v
If
the stroke measuring sensor fails, the WECS system switches the ICU to a pure
time control and triggers the signal based on the timing of the neighbouring
cylinders.