1.   What are the precautions involved in running with RT flex



    Reliability and safety has the utmost priority in the common rail RT-flex system.

v  The duplicated high-pressure delivery pipes have stop cocks at both ends to isolate any failed pipe. Each single pipe is adequate for the full delivery. All high pressure pipes are double-walled for safety.

v  Every injection nozzle is independently monitored and controlled by the WECS. In case of difficulties, such as a broken high pressure line or a malfunctioning injector, the affected injection valve can be cut out individually without losing the entire cylinder.

v  If the stroke measuring sensor fails, the WECS system switches the ICU to a pure time control and triggers the signal based on the timing of the neighbouring cylinders.