Tuesday, December 17, 2013
Hot lay-up, Cold lay-up
Hot lay-up
Hot lay-up condition, the machinery is kept in operation for the sake of fast re-commissioning, but measures
may be taken to reduce various operational costs.
Cold lay-up
In cold lay-up condition the machinery is taken out of service and the vessel is kept “electrically dead” with the
exception of emergency power.
Hot lay-up condition, the machinery is kept in operation for the sake of fast re-commissioning, but measures
may be taken to reduce various operational costs.
Cold lay-up
In cold lay-up condition the machinery is taken out of service and the vessel is kept “electrically dead” with the
exception of emergency power.
Single Phasing of a Motor?
Single Phasing of a Motor?
Single Phasing is where one of the 3-phase's supplying the Motor becomes disconnected. The Motor will continue to run if this happens and can result in Motor Burnout. The effect of Single Phasing is to increase the Current in the two remaining Lines and cause the Motor to become very noisy due to uneven Torque produced
How is 15ppm reached in an Oily Water Separator?
How is
15ppm reached in an Oily Water Separator?
15ppm is
achieved in an Oily Water Separator by normally passing through a Two Stage
Separator where in the first stage Oil/Water is passed into the coarse
separating compartment. Here some oil will rise to the top of the Compartment
due to its lower density, Heating Coils may aid this.
The remaining Oil/Water will flow down into
the Fine separating Compartment and moves slowly between Catch Plates. More Oil will separate out onto the underside
of these Plates and travel outwards until free to rise to the oil collecting
space.
The almost Oil Free Water
(usually being at 100ppm at this stage) will then pass to the second stage of
the separator, which is a Filter Unit comprising of two Filter Units.
The first Filter Stage removes Physical
Impurities present and promotes some Fine Separation.
The second Stage Filter uses Coalescer Inserts
to achieve the fina, Oil/Water Mixture leaving this Stage at less
than 15ppm.
Why is Simultaneous Injection of Fuel Oil and Starting Air into a Main Engine Cylinder Undesirable and How is it Prevented?
Why is
Simultaneous Injection of Fuel Oil and Starting Air into a Main Engine Cylinder
Undesirable and How is it Prevented?
Simultaneous
Injection of Fuel and Starting Air into a Cylinder is Undesirable as it could
lead to an Explosion in the Start Air System.
It is
prevented by means of Interlock, which prevents Fuel being Injected when the
Air Start Auto Valve is Open.
The
Interlock Operates a Stop Solenoid, which keeps the Fuel Rack at Zero Position.
What are the Safety Devices fitted to an Air Compressor?
What are
the Safety Devices fitted to an Air Compressor?
Low Lub
Oil Pressure Shut Down
High Air
Temperature Shut Down
1st Stage
Relief Valve
2nd Stage
Relief Valve
A Fusible
Plug is fitted after the 2nd Stage Cooler, Set at 120°C
If Water
Cooled, a Jacket Water Safety Valve is fitted.
What is the Primary Function of the Expansion Valve in a Refrigeration System?
What is
the Primary Function of the Expansion Valve in a Refrigeration System?
The
Primary Function of an Expansion Valve in a Refrigeration System is to regulate
the Flow of Refrigerant from the H P side to the L P side of the System.
The
pressure drop causes the Saturation Temperature to drop, enabling it to boil
off at the Low Temperature of the Evaporator.
Subscribe to: